Industrial Air Flow Detection Dust Switch (HTW-AS-33)
Introduction:
HTW-AS-33 differential pressure switches can sense the pressure difference , vacuum, over pressure, poor flow of the incorrosive gas.
Conventional applications include :
+ Monitoring Filters blocked Alarm Device
+ Monitoring air blower running status.
+ Monitoring air of ventilative pipelines
+ Controlling the largest gas flow of variable gas volume
+ Monitoring the gas of combustion furnace.
Product parameters:
Measuring range |
20Pa~200Pa |
Max.differential pressure |
12000Pa |
Degree of protection |
IP54 |
Electrical rating value |
<2A / 250VAC |
Working temperature |
15~+60 |
Storage temperature |
-40~85 |
Min. actuating pressure |
standard: 20Pa;min.starting |
----------------------------------- interval:10Pa(range: 20~30Pa)
Linearity: range 50~500Pa <±3Pa
Installation direction: vertical(standard installation style)
Hose connection: pipeΦ6.2mm
Weight: 100 grams without bracket
Repeatability: <±0.025mbarIn the ranges 0.2 to 2mbar
Installation:
Location: select a location where vibrations are minimal .Ambient temperature should be within the range of -15 / +60.The production calibration of the SA101 is made at room temperature ; mounting locations close to room temperatures are preferred . In systems with high humidity where condensation is possible, thus the entrance should point downwards.
Pressure connection and wiring:
Pressure connections are marked with P1
⊕&P2
Θ,incorrect connections are forbidden.
Mounting instruction:
The switch is preferably mounted with the diaphragm in a vertical plane , unless the device is set or calibrated for horizontal mounting as on special customer models. On these models the mountingposition is indicated on the side of the control .It may be fastened directly to the duct,heater or panel as long as the mounting surface has minimal or no vibration .Pressure connections are marked +(high pressure ) and - (low or static pressure) .For more informaton, please read the diagram on the side of the control.
Note:
To drill a hole through the plastic tube or pipe before installation, and also mount part of L-bracket on the spot(Standard setting).
Accessory consists of:
(Φ6.2mm1.8m) plastic tubes,
1 L-bracket, 3srews, 2 pressure-adapted tubes.
Caution:
+ The Pressure Switch should be mounted vertically which can prevent affecting on precision from inner atmosphere film weight.
+ To prevent electrical shock or damage to equipment , when the cover is removed ,ensure the power supply is switched off.
+ Complete wiring and check the connections before applying power . Incorrectwiring may cause permanent damage to the unit.
Wiring (Screw terminal):
If the actual pressure is below dial setting, 1-2closed, while if the actual pressure is over dial setting, 1-3 closed.
System check:
After proper installation and adjustment of the control ,the system should be checked by running at least one full cycle of the equipment .If anything appears to operate incorrectly , the wiring and components should be rechecked.
Repair and replacement:
Repair is not possible .In case of a defective or improperly functioning control ,please check with your nearest supplier . when contacting the supplier for a replacement ,you should state the type /model number of the control .this number can be found on the side of the control.
Specifications
Air Differential Pressure Switch
1.Material:plastic
2.Max.Working pressure:10Kpa
3.Protection class:IP54
Air Differential Pressure Switch
AFS930.8x Series
Application:
It is used to monitoring overload pressure and of the air /noninflammability/noncorrosive and differential pressure. Can be applicable to the following site:
The air filter and ventilator
The industrial refrigerating air circulation
The electric heater overheating protection
The air flow in vent pipe
The heat exchanger freeze-proofing protection
The monitoring of the pressure and level of the storage tank and pressure vessel
Model:
The air differential pressure value can be set according to adjusting the knob, no need to connect the pressure meter. Return difference controlling achieve by adjusting the " -" screw.
The differential pressure value indicating the vertical installing, when horizontal installing, the true value is higher 20Pa than the setting value
Company Profile
FAQ
Q1:What is the unit price?
A.:The unit price varies according to different specific requirements, we are more than pleased to quote you the best price once get your specific application. e.g. W/O Modbus, W/O key-card, 2/4 pipe system, W/O customized programming...
Anyway, we are always ready to discuss details with you via Email.
Q2:What is the MOQ, small quantities accetaple?
A.: Commonly the MOQ for us is 500pcs, however, we also accept small quantities or Sample orders as starting.
Q3:How is your products' quality and warrenty?
A.:All of our products meet EU standards, samples are available for quality evaluation; all products are with 18 months warrenty.
Q4:Can I print my logo on the products, and customize my own designed packing?
A.:100% YES, but the order quantity shall be over MOQ, or else, extra costs will be charged.
Q5:Do you supply OEM or ODM?
A.:Yes, we have strong R&D sources and production ability, and already helping many international companies OEM/ODM cases with highly positive feedback.
Q6:Why should I buy products from your company?
A.:That's really a good question, Quality Products but with Competitive Price, Timely Delivery, Professional and Fast Reacton, ...
In a word, WE ARE DIFFERENT, why not just try from the Email...
Welcome to contact us
Hotowell International Co.,Limited
Add:Room 1406-2, No.11 Duiying Road, jimei district, Xiamen, 361021, China
Air Flow Switch | Flow Switch | Differential Pressure Switch